MTL5575 Temperature Converter THC or RTD 5500 Series IS Inte
Delivery time:in stock
Payment Terms: Paypal, Aliexpress, Western Union, T/T
MOQ: 1pcs
Specifications
MTL5575 Temperature Converter THC or RTD 5500 Series IS Inte
Trade information of MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
Order code: MTL5575 Type:Temperature Input
Description:DC low level temperature sensor signal converter into 4/20mA + Alarm Brand:MTL
Serie:IS Isolator 5500 series Minimum quantity:1 Offset:1
Specifications of MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
In- and outputs: Temperature converter
Mounting method: DIN-rail
Number of channels: 1
Extra alarm output: Yes
Description of MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
IS Isolators, 4500 & 5500 series. Galvanic isolation solutions with low power dissipation and quick install and release mechanism. Most Isolators are multichannnel and have broken line monitoring.
The backplane mounting range MTL4500 is designed with systme vendors in mind for project focussed applications. A Multiway connector to the backplane provides safe-area and power supply connections, while hazardous-area connections plug into the front of the module, simplifying installation and maintenance
The DIN rail mounting MTL 5500 range meets the needs of the IS interface market for application focussed projects. The 5500 clips quickly onto a DIN rail, so it is compatible with the industry- standard mounting system. Wiring is simplified by plug in safe- and hazardous area connectors, and a power plug which accepts a power bus.
Line fault detection facilities are provided accross the range. In addition status LEDs and configuration switches are located on the top or side of the indvidual modules.
MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
The MTL5500 series is the latest generation of MTL isolators. Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on the success of the MTL5000 series to bring the benefits of galvanic isolation with exceptional design and reliability.,II (I) GD (Ex ia) IIC,IECEx, ATEX (Baseefa) FM, CSA
MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
These modules accept inputs from low-level dc sources such as thermocouples or RTDs in hazardous
areas and converts them into 4/20mA signals to drive safe area loads.
Early burnout detection (EBD)
When EBD is selected, the resistance of the thermocouple circuit is monitored and an alarm is
raised when there is an increase of more than 50m. This enables preventative maintenance to be
conducted on the field installation before the thermocouple actually breaks.
Configuration using PCS45/PCL45USB
Use PCS45 software, in conjunction with the PCL45USB serial link, to configure these modules. Instructions
are contained within the software.
MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
• Single channel, THC or RTD input with alarm
• The MTL5575 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safe-area load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for all thermocouple types and 2, 3 or 4-wire RTDs.
• (For thermocouple applications the HAZ-CJC plug, on terminals 1–3, includes an integral CJC sensor). Configuration is carried out using a personal computer – see section 6.9.
• A single alarm output is provided and may be configured for process alarm or to provide notice of early thermocouple failure.
MTL5575 Temperature Converter THC or RTD 5500 Series IS Interface Units
The MTLx575 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safe area load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for all thermocouple types and 2-, 3- or 4-wire RTDs. (For thermocouple applications the HAZ-CJC plug on terminals 1–3 includes an integral CJC sensor). Configuration is carried out using a personal computer. A single alarm output is provided and may be configured for process alarm or to provide notice of early thermocouple failure.
• 3-Port Isolation
• High Packing density
• Low power dissipation
• Multi-channel I/O modules
• Compatible with preceding MTL5000 series
• Assessed for Functional safety IEC61508 applications
• Required EX numbers and information displayed on cover where applicable
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC’s, etc.
We mainly supply YOKOGAWA, Siemens, Honeywell , Rosemount, Endress Hauser, ABB, Weidmuller, ABB, MOELLER, Schneider Electic ,Omron ,Fluke ,PEPPERL+FUCHS,etc.
Why choose us?
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3. SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
Packaging:
Imported with original packaging or standard export packing.Customize design is acceptable.
Contact
Wuhan Xieyuan Automation Equipment Co., Ltd
Telephone:86-027-85583233
Mobile Phone:86-18671080257
Fax:86-027-85309780
Contact:victor@whxyauto.com
Skype:victordu963@gmail.com
Whatsapp&Viber are available
Address:7-A16,Caishen Commercial Plaza,Hankou Railway Station